Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

Tan Shengjian, Qiu Xia, Li Guanghui, Zhao Bingcheng, Liang Yuqing. Determination of puerarin in Gegen qinlian pian by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 1996, (5): 295-297.
Citation: Tan Shengjian, Qiu Xia, Li Guanghui, Zhao Bingcheng, Liang Yuqing. Determination of puerarin in Gegen qinlian pian by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 1996, (5): 295-297.

Determination of puerarin in Gegen qinlian pian by RP-HPLC

  • A quantitative method was developed for the determination of puerarin in Gegen Qing lian Pian by reversed phase HPLC.Chromatographic conditions included column ODS-C(10),column temperature,35℃;detector UV,250nm;mobile phase,methanol-water(23:77),flow rate 1 ml/min;injecting volume,10μl;external standad.the number of theoretical plates calculated by puerarin peak was no less than 2000.The standard curve was linear in the concentration range of 5μg/ml-80μg/ml,and correlation coefficient was 0.9999.The average rccovery and the relative standsrd deviation were 97.6% and 1.8%,respectively.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2328) PDF downloads(586) Cited by()

Related
Proportional views

Determination of puerarin in Gegen qinlian pian by RP-HPLC

Abstract: A quantitative method was developed for the determination of puerarin in Gegen Qing lian Pian by reversed phase HPLC.Chromatographic conditions included column ODS-C(10),column temperature,35℃;detector UV,250nm;mobile phase,methanol-water(23:77),flow rate 1 ml/min;injecting volume,10μl;external standad.the number of theoretical plates calculated by puerarin peak was no less than 2000.The standard curve was linear in the concentration range of 5μg/ml-80μg/ml,and correlation coefficient was 0.9999.The average rccovery and the relative standsrd deviation were 97.6% and 1.8%,respectively.

Tan Shengjian, Qiu Xia, Li Guanghui, Zhao Bingcheng, Liang Yuqing. Determination of puerarin in Gegen qinlian pian by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 1996, (5): 295-297.
Citation: Tan Shengjian, Qiu Xia, Li Guanghui, Zhao Bingcheng, Liang Yuqing. Determination of puerarin in Gegen qinlian pian by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 1996, (5): 295-297.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return