Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

Fu Yinghua, Xu Hongxiang. Studies on UV spectrophotometric determination and thinlayer chromatographic identification of tetracaine hydrochloride eye drop[J]. Journal of Pharmaceutical Practice and Service, 1998, (4): 230-232.
Citation: Fu Yinghua, Xu Hongxiang. Studies on UV spectrophotometric determination and thinlayer chromatographic identification of tetracaine hydrochloride eye drop[J]. Journal of Pharmaceutical Practice and Service, 1998, (4): 230-232.

Studies on UV spectrophotometric determination and thinlayer chromatographic identification of tetracaine hydrochloride eye drop

  • A method of determination by UV spectrophotometry and identification by thin-layer chromatography of tetracaine hydrochloride eye drop was established. The maximum absorbance wavel ength at 310±1nm was selected for determination wavelength, ethyl hydroxybenzoate has no interferrence. The result showed that the absorbance coeffecient (E1cm1%) of tetracaine hydrochloride at 310±1nm was 760,RSD=0.5% (n=20), the mean recovery for sample was 99.5%, RSD=0.5% (n=7). This method is simple, rapid, accurate and reproducible.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2341) PDF downloads(286) Cited by()

Related
Proportional views

Studies on UV spectrophotometric determination and thinlayer chromatographic identification of tetracaine hydrochloride eye drop

Abstract: A method of determination by UV spectrophotometry and identification by thin-layer chromatography of tetracaine hydrochloride eye drop was established. The maximum absorbance wavel ength at 310±1nm was selected for determination wavelength, ethyl hydroxybenzoate has no interferrence. The result showed that the absorbance coeffecient (E1cm1%) of tetracaine hydrochloride at 310±1nm was 760,RSD=0.5% (n=20), the mean recovery for sample was 99.5%, RSD=0.5% (n=7). This method is simple, rapid, accurate and reproducible.

Fu Yinghua, Xu Hongxiang. Studies on UV spectrophotometric determination and thinlayer chromatographic identification of tetracaine hydrochloride eye drop[J]. Journal of Pharmaceutical Practice and Service, 1998, (4): 230-232.
Citation: Fu Yinghua, Xu Hongxiang. Studies on UV spectrophotometric determination and thinlayer chromatographic identification of tetracaine hydrochloride eye drop[J]. Journal of Pharmaceutical Practice and Service, 1998, (4): 230-232.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return