Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

CHEN Sai-zhen, YUAN Guo-ping, HU Da-ping, CHEN Yue-bin. Determination of rifampicin concentration in human serum by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2000, (4): 225-227.
Citation: CHEN Sai-zhen, YUAN Guo-ping, HU Da-ping, CHEN Yue-bin. Determination of rifampicin concentration in human serum by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2000, (4): 225-227.

Determination of rifampicin concentration in human serum by RP-HPLC

  • Received Date: 2000-02-20
  • OBJECTIVE To determine the concentration of rifampicin in human serum by RP-HPLC.METHODS Serum was precipitated with centrifugation after add ed 4 times of methanol,and its super-stratum clear fluid was injected after filtration with 0.45μ micro-pore filter membrane.The method used Nova-Pak C18 column as chromatogram column,methanol-acetate buffer solution as flow phase,chlordiazepoxide as internal standard.The detection wavelength was 334nm.RESULTS The linear range of rifampicin was 1~25μg/ml.Average recovery was (100.9±4.2)%.Daily and daytime RSD were less than 4%.The lowest detection limit was 0.5μg/ml(the rate of signal and noise was greater than or equal to 3).CONCLUSION This method is simple,reliable and indicated for clinical monitoring.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1999) PDF downloads(879) Cited by()

Related
Proportional views

Determination of rifampicin concentration in human serum by RP-HPLC

Abstract: OBJECTIVE To determine the concentration of rifampicin in human serum by RP-HPLC.METHODS Serum was precipitated with centrifugation after add ed 4 times of methanol,and its super-stratum clear fluid was injected after filtration with 0.45μ micro-pore filter membrane.The method used Nova-Pak C18 column as chromatogram column,methanol-acetate buffer solution as flow phase,chlordiazepoxide as internal standard.The detection wavelength was 334nm.RESULTS The linear range of rifampicin was 1~25μg/ml.Average recovery was (100.9±4.2)%.Daily and daytime RSD were less than 4%.The lowest detection limit was 0.5μg/ml(the rate of signal and noise was greater than or equal to 3).CONCLUSION This method is simple,reliable and indicated for clinical monitoring.

CHEN Sai-zhen, YUAN Guo-ping, HU Da-ping, CHEN Yue-bin. Determination of rifampicin concentration in human serum by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2000, (4): 225-227.
Citation: CHEN Sai-zhen, YUAN Guo-ping, HU Da-ping, CHEN Yue-bin. Determination of rifampicin concentration in human serum by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2000, (4): 225-227.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return