Determination of magnolol in Jierekangyan No.I oral solution by HPLC
- Received Date: 2000-08-02
-
Key words:
- oral solution /
- magnolol /
- TLC /
- HPLC
Abstract: OBJECTIVE To establish a method of quality control for Jierekangyan No.1(JRKY) oral solution by qualitatively and quantitatively determining the active substance of magnolol in the solution.METHODS Analyse magnolol qualitatively by TLC and quantitatively on ODS-C18 column with MeOH-water(70:30) as mobile phase,to determine the content of magnolol by HPLC.RESULTS The average recovery was 98.15%(RSD=2.96%).The linear concentration range of the method was 0.0148~0.148μg/ml, r =0.9996.CONCLUSION The qualitative and the quantitative methods studied are rapid,reliable and sensitive.
Citation: | FANG Zhi-zhong, YANG Jin-rong, LI Xin, LI Lu, ZHANG Qing-Wei, . Determination of magnolol in Jierekangyan No.I oral solution by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2001, (2): 96-98. |