Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

LI Ping, YANG Jie. Determination of paeoniflorin in Yiganning capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 226-228.
Citation: LI Ping, YANG Jie. Determination of paeoniflorin in Yiganning capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 226-228.

Determination of paeoniflorin in Yiganning capsule by HPLC

  • Received Date: 2004-03-07
  • Objective To develop a method for the determination of paeoniflorin in Yiganning capsule by HPLC has been developed. Methods Chromatographic analysis was carried out on a ZORBAX RX-SIL column (150mm×4.6mm, 5μm) with n-hexane and dichloromethane and methanol and strong ammonia water (270:270:20:1.7, volume ratio) as mobile phase. The detection wavelength was 254nm (band width 2nm) and reference wavelength 550nm (band width 100nm). 1mL of supernatant were injected. ResultsThe linear range was well (r=0.9995), the averang recovery of paeoniflorin was 97.8% (n = 5), and the relative standard deviation was 1.9%. Conclusion This method is accurate, sensible and reproducible.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2400) PDF downloads(335) Cited by()

Related
Proportional views

Determination of paeoniflorin in Yiganning capsule by HPLC

Abstract: Objective To develop a method for the determination of paeoniflorin in Yiganning capsule by HPLC has been developed. Methods Chromatographic analysis was carried out on a ZORBAX RX-SIL column (150mm×4.6mm, 5μm) with n-hexane and dichloromethane and methanol and strong ammonia water (270:270:20:1.7, volume ratio) as mobile phase. The detection wavelength was 254nm (band width 2nm) and reference wavelength 550nm (band width 100nm). 1mL of supernatant were injected. ResultsThe linear range was well (r=0.9995), the averang recovery of paeoniflorin was 97.8% (n = 5), and the relative standard deviation was 1.9%. Conclusion This method is accurate, sensible and reproducible.

LI Ping, YANG Jie. Determination of paeoniflorin in Yiganning capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 226-228.
Citation: LI Ping, YANG Jie. Determination of paeoniflorin in Yiganning capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 226-228.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return