LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.
Citation: LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.

Determination of atropine sulfate eye drops by ion-pair HPLC

  • Received Date: 2004-03-04
  • Objective An ion-pair HPLC method was developed for determination of atropine sulfate in atropine sulfate eye drops. Methods Alltech-C18 (4.6×250mm, 5μm)column was used and the mobile phase was acetonitrile -0.05mol/L sodium hep-tanesul fonate (35:65). It was detected at 210nm. ResultsLinearity was obtained in the concentration rage of 8-120μg/mL, A=-72915.4073 + 15308.1639C,r=0.999. The average recoveries was 100.2%, RSD = 0.65%. Conclusion The method provide a accurate and sensitive way for the determination of atropine sulfate in atropine sulfate eye drops by ion-pair HPLC.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3047) PDF downloads(466) Cited by()

Related
Proportional views

Determination of atropine sulfate eye drops by ion-pair HPLC

Abstract: Objective An ion-pair HPLC method was developed for determination of atropine sulfate in atropine sulfate eye drops. Methods Alltech-C18 (4.6×250mm, 5μm)column was used and the mobile phase was acetonitrile -0.05mol/L sodium hep-tanesul fonate (35:65). It was detected at 210nm. ResultsLinearity was obtained in the concentration rage of 8-120μg/mL, A=-72915.4073 + 15308.1639C,r=0.999. The average recoveries was 100.2%, RSD = 0.65%. Conclusion The method provide a accurate and sensitive way for the determination of atropine sulfate in atropine sulfate eye drops by ion-pair HPLC.

LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.
Citation: LI Zhi-mei, LIU Meng, ZHANG Huang-dan. Determination of atropine sulfate eye drops by ion-pair HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 230-232.