Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

GU Wei-ying, ZHANG He-ping, HUANG Wei-fen, GU Hong-jun. Determination of compound dexamethason acetate liniment[J]. Journal of Pharmaceutical Practice and Service, 2005, (3): 167-169.
Citation: GU Wei-ying, ZHANG He-ping, HUANG Wei-fen, GU Hong-jun. Determination of compound dexamethason acetate liniment[J]. Journal of Pharmaceutical Practice and Service, 2005, (3): 167-169.

Determination of compound dexamethason acetate liniment

  • Received Date: 2005-02-18
  • Objective To establish a quantitative analysis method for camphor and dexamethason acetate in compound dexametha son acetate liniment.Methods The camphor was determined directly at 305nm by first derivative spectrometry.The dexamethason acetate was determined at 485nm by seeable spectrometry.Results The calibra-tion curve of camphor was linear in the range from 1.62-3.22mg/mL with r=0.999 4,the average recovery and relative standard deviation were 99.89% and 0.34% respectively.The calibration curve of dexamethason acetate was linear in the range from 122.04-227.81μg/mL with r= 0.9997, the average recovery and RSD were 99.18% and 1.32% respectively.Conclusions The method is simple, rapid and accurate.It can be used to control the quality of compound dexame-thason acetate liniment.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2484) PDF downloads(441) Cited by()

Related
Proportional views

Determination of compound dexamethason acetate liniment

Abstract: Objective To establish a quantitative analysis method for camphor and dexamethason acetate in compound dexametha son acetate liniment.Methods The camphor was determined directly at 305nm by first derivative spectrometry.The dexamethason acetate was determined at 485nm by seeable spectrometry.Results The calibra-tion curve of camphor was linear in the range from 1.62-3.22mg/mL with r=0.999 4,the average recovery and relative standard deviation were 99.89% and 0.34% respectively.The calibration curve of dexamethason acetate was linear in the range from 122.04-227.81μg/mL with r= 0.9997, the average recovery and RSD were 99.18% and 1.32% respectively.Conclusions The method is simple, rapid and accurate.It can be used to control the quality of compound dexame-thason acetate liniment.

GU Wei-ying, ZHANG He-ping, HUANG Wei-fen, GU Hong-jun. Determination of compound dexamethason acetate liniment[J]. Journal of Pharmaceutical Practice and Service, 2005, (3): 167-169.
Citation: GU Wei-ying, ZHANG He-ping, HUANG Wei-fen, GU Hong-jun. Determination of compound dexamethason acetate liniment[J]. Journal of Pharmaceutical Practice and Service, 2005, (3): 167-169.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return