WANG Hui, ZHANG Guo-qing. Determination of ropivacaine in human plasma by reversed-phase high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2007, (4): 238-240.
Citation: WANG Hui, ZHANG Guo-qing. Determination of ropivacaine in human plasma by reversed-phase high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2007, (4): 238-240.

Determination of ropivacaine in human plasma by reversed-phase high performance liquid chromatography

  • Received Date: 2006-03-23
  • Objective: To establish an accurate and rapid method for determination of ropivacaine by RP-HPLC. Methods: The sample was treated by the addition of bupivacaine as an internal standard,extraction with aether and n-hexane,and dryed by N2.The residue dissolved in the mobile phase and injected into chromatographic system.The HPLC system consisted of AgilentC18 column(4.6 mm×150 mm,5μm)and mobile phase of 0.045 mol/L KH2PO4(pH3.0)-methol(55:45).Velocity of flow was 1.0 mL/min.The detection wavelength was 210 nm.Column temperature was 30℃. Results: The linear range was from 0.2509μg/mL to 5.018μg/mL with r of 0.999 6,the average recovery was 102.0%.RSD of Intra-day and Inter-day<15%.The results were accord with methodology. Conclusion: This method is quick and stable for ropivacaine monitoring in clinical research.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2551) PDF downloads(28) Cited by()

Related
Proportional views

Determination of ropivacaine in human plasma by reversed-phase high performance liquid chromatography

Abstract: Objective: To establish an accurate and rapid method for determination of ropivacaine by RP-HPLC. Methods: The sample was treated by the addition of bupivacaine as an internal standard,extraction with aether and n-hexane,and dryed by N2.The residue dissolved in the mobile phase and injected into chromatographic system.The HPLC system consisted of AgilentC18 column(4.6 mm×150 mm,5μm)and mobile phase of 0.045 mol/L KH2PO4(pH3.0)-methol(55:45).Velocity of flow was 1.0 mL/min.The detection wavelength was 210 nm.Column temperature was 30℃. Results: The linear range was from 0.2509μg/mL to 5.018μg/mL with r of 0.999 6,the average recovery was 102.0%.RSD of Intra-day and Inter-day<15%.The results were accord with methodology. Conclusion: This method is quick and stable for ropivacaine monitoring in clinical research.

WANG Hui, ZHANG Guo-qing. Determination of ropivacaine in human plasma by reversed-phase high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2007, (4): 238-240.
Citation: WANG Hui, ZHANG Guo-qing. Determination of ropivacaine in human plasma by reversed-phase high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2007, (4): 238-240.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return