HUANG Jin-hua, MAO Gui-fu, WU Rong, LING Yi. Determination of chlorhexidine acetate in appliance-preserving solution by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (1): 48-50.
Citation: HUANG Jin-hua, MAO Gui-fu, WU Rong, LING Yi. Determination of chlorhexidine acetate in appliance-preserving solution by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (1): 48-50.

Determination of chlorhexidine acetate in appliance-preserving solution by RP-HPLC

  • Received Date: 2007-03-27
  • Rev Recd Date: 2007-06-18
  • Objective: To develop a RP-HPLC method for determination of chlorhexidine acetate in appliance preserving solution. Methods: RP-HPLC was used for the determination of chlorhexidine acetate in appliance's preserving solution on a Shim-pack CLC-C8 column, with acetonitrile-water (including 1% triethylamine,adjecting pH to 4.0 by glacial acetate)(42-58)as mobile phase.The detection wavelength was 258 nm,flow rate was 1.0 mL/min, column temperature was 30 ℃,sample injection volume was 20 μL. Results: Chlorhexidine acetate had a good linear coefficient (r=0.999 8) over the range of 20-80 μg/mL.The average recoveries of chlorhexidine acetate was 99.96%,RSD=1.71% (n=6). Conclusion: This method was quick and accurate for determination of chlorhexidine acetate in appliance preserving solution.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2653) PDF downloads(1044) Cited by()

Related
Proportional views

Determination of chlorhexidine acetate in appliance-preserving solution by RP-HPLC

Abstract: Objective: To develop a RP-HPLC method for determination of chlorhexidine acetate in appliance preserving solution. Methods: RP-HPLC was used for the determination of chlorhexidine acetate in appliance's preserving solution on a Shim-pack CLC-C8 column, with acetonitrile-water (including 1% triethylamine,adjecting pH to 4.0 by glacial acetate)(42-58)as mobile phase.The detection wavelength was 258 nm,flow rate was 1.0 mL/min, column temperature was 30 ℃,sample injection volume was 20 μL. Results: Chlorhexidine acetate had a good linear coefficient (r=0.999 8) over the range of 20-80 μg/mL.The average recoveries of chlorhexidine acetate was 99.96%,RSD=1.71% (n=6). Conclusion: This method was quick and accurate for determination of chlorhexidine acetate in appliance preserving solution.

HUANG Jin-hua, MAO Gui-fu, WU Rong, LING Yi. Determination of chlorhexidine acetate in appliance-preserving solution by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (1): 48-50.
Citation: HUANG Jin-hua, MAO Gui-fu, WU Rong, LING Yi. Determination of chlorhexidine acetate in appliance-preserving solution by RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (1): 48-50.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return