GAO Jin, FU Cong, JI Yang, NIE Yu-Qiong, HU Dan. Application of bacterial endotoxin test to compound pralidoxime chloride injection[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 133-135.
Citation: GAO Jin, FU Cong, JI Yang, NIE Yu-Qiong, HU Dan. Application of bacterial endotoxin test to compound pralidoxime chloride injection[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 133-135.

Application of bacterial endotoxin test to compound pralidoxime chloride injection

  • Received Date: 2007-09-01
  • Objective: To establish an application of bacterial endotoxin test to compound pralidoxime chloride injection. Methods: The expriment was carried out based on the bacterial endotoxin test in Chinese pharmacopoeia 2005 edition. Results: It was proved that the maximum noninterference concentration of compound pralidoxime chloride injection was pralidoxime chloride 10 mg/mL and the sensitivity of TAL was 0.25 EU/mL. Conclusion: The results suggested that the bacterial endotoxin test was suitable for the detection of endotoxin in compound pralidoxime chloride injection and the bacterial endotoxin limit was 0.2 EU/mg.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2230) PDF downloads(196) Cited by()

Related
Proportional views

Application of bacterial endotoxin test to compound pralidoxime chloride injection

Abstract: Objective: To establish an application of bacterial endotoxin test to compound pralidoxime chloride injection. Methods: The expriment was carried out based on the bacterial endotoxin test in Chinese pharmacopoeia 2005 edition. Results: It was proved that the maximum noninterference concentration of compound pralidoxime chloride injection was pralidoxime chloride 10 mg/mL and the sensitivity of TAL was 0.25 EU/mL. Conclusion: The results suggested that the bacterial endotoxin test was suitable for the detection of endotoxin in compound pralidoxime chloride injection and the bacterial endotoxin limit was 0.2 EU/mg.

GAO Jin, FU Cong, JI Yang, NIE Yu-Qiong, HU Dan. Application of bacterial endotoxin test to compound pralidoxime chloride injection[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 133-135.
Citation: GAO Jin, FU Cong, JI Yang, NIE Yu-Qiong, HU Dan. Application of bacterial endotoxin test to compound pralidoxime chloride injection[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 133-135.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return