PIAO Shu-juan, ZHANG Chun, JIANG Chun-xia, LIN Hou-Wen, CHEN Wan-sheng. Determination of lincomycin hydrochloride in lincomycin cream by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (5): 357-358,361.
Citation: PIAO Shu-juan, ZHANG Chun, JIANG Chun-xia, LIN Hou-Wen, CHEN Wan-sheng. Determination of lincomycin hydrochloride in lincomycin cream by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (5): 357-358,361.

Determination of lincomycin hydrochloride in lincomycin cream by HPLC

  • Received Date: 2007-10-15
  • Objective:To establish high performance liquid chromatography method for determination the content of lincomycin hydrochloride in lincomycin cream.Methods:A YMC C18(250 mm×4.6 mm,5μm)column was used with the mobile phase of 0.05mol/L borax (adjust pH to 6.0 with phosphoric acid)-methanol (55:45)and UV wavelengh of 214 nm.Results:The calibration curve of lincomycin hydrochloride was line in the range of 10~30μg(r=0.999 7).The average recovery was 98.74%(RSD= 2.06%,n=9).The relative content of lincomycin hydrochloride in three batch of lincomycin cream was 96.21%,96.50% and 93.38%.Conclusion:This method is simple,quick,accurate and suitable for the quality control of lincomyein cream.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2531) PDF downloads(416) Cited by()

Related
Proportional views

Determination of lincomycin hydrochloride in lincomycin cream by HPLC

Abstract: Objective:To establish high performance liquid chromatography method for determination the content of lincomycin hydrochloride in lincomycin cream.Methods:A YMC C18(250 mm×4.6 mm,5μm)column was used with the mobile phase of 0.05mol/L borax (adjust pH to 6.0 with phosphoric acid)-methanol (55:45)and UV wavelengh of 214 nm.Results:The calibration curve of lincomycin hydrochloride was line in the range of 10~30μg(r=0.999 7).The average recovery was 98.74%(RSD= 2.06%,n=9).The relative content of lincomycin hydrochloride in three batch of lincomycin cream was 96.21%,96.50% and 93.38%.Conclusion:This method is simple,quick,accurate and suitable for the quality control of lincomyein cream.

PIAO Shu-juan, ZHANG Chun, JIANG Chun-xia, LIN Hou-Wen, CHEN Wan-sheng. Determination of lincomycin hydrochloride in lincomycin cream by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (5): 357-358,361.
Citation: PIAO Shu-juan, ZHANG Chun, JIANG Chun-xia, LIN Hou-Wen, CHEN Wan-sheng. Determination of lincomycin hydrochloride in lincomycin cream by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2008, (5): 357-358,361.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return