Identification and determination of scutellarin in compound granule tetrandra
doi: 10.3969/j.issn.1006-0111.2016.03.013
- Received Date: 2014-12-01
- Rev Recd Date: 2015-03-23
-
Key words:
- compound granule tetrandra /
- sculellaria barbata /
- scutellarin /
- TLC /
- HPLC
Abstract: Objective To develop the methods for identification and determination of scutellarin in compound Granule Tetrandra. Methods A TLC method was used to identify quality for scutellarin, and a HPLC method was used to determine the content of scutellarin. Results The spot was clear in TLC identification without interference of negative control. The sample size of scutellarin had a good linear relationship with peak area r=0.9996(n=5)when ranged from 22.4~156.8 μg/ml, with the average recovery rate 97.79%(RSD=0.32%, n=6). Conclusion The method is simple, with good specificity and reproducibility, which can be used as the quality control for this preparation.
Citation: | ZHANG Shuyu, XU Jianjiang, YU Yanli, BI Yunsheng, ZHAO Wenjing, LIU Qian, LIU Tongqi. Identification and determination of scutellarin in compound granule tetrandra[J]. Journal of Pharmaceutical Practice and Service, 2016, 34(3): 245-248. doi: 10.3969/j.issn.1006-0111.2016.03.013 |