Optimization of assay method for loganin in Gandi capsules
doi: 10.3969/j.issn.1006-0111.2018.06.016
- Received Date: 2018-06-01
- Rev Recd Date: 2018-09-10
-
Key words:
- Gandi capsule /
- loganin /
- assay /
- HPLC
Abstract: Objective To establish a HPLC method for the assay of loganin in Gandi capsules. Methods The Waters Symmtry column C18 (4.6 mm×150 mm, 5 μm) was used with acetonitrile-water (13:87) as mobile phase. The flow rate was 1.0 ml/min and the detection wavelength at 240 nm. Results The calibration curves were linear within the range of 0.030 1-3.01 μg (r=0.999 9) for loganin. The average recovery and relative standard deviation of loganin were 99.62% and 0.86%. Conclusion This method is simple, practicable, accurate and fast. It can be used to assay loganin in Gandi capsules.
Citation: | WEI Xin, XU Renjie, TANG Ying, YAO Huan, XU Ajing, ZHANG Jian. Optimization of assay method for loganin in Gandi capsules[J]. Journal of Pharmaceutical Practice and Service, 2018, 36(6): 551-553. doi: 10.3969/j.issn.1006-0111.2018.06.016 |