Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

HAN Jia-yi, ZHENG Guo-gang. Method verify on quantity of organic solvents remaining[J]. Journal of Pharmaceutical Practice and Service, 2003, (6): 355-357.
Citation: HAN Jia-yi, ZHENG Guo-gang. Method verify on quantity of organic solvents remaining[J]. Journal of Pharmaceutical Practice and Service, 2003, (6): 355-357.

Method verify on quantity of organic solvents remaining

  • Received Date: 2003-10-28
  • OBJECTIVE To establish a GC method for the determination of organic solvents remaining. METHODS The methods was approved by high efficiency chlomatogram column of INNOWAX(30m×0.32mm×0.25μm),with a detector of FID using direct injection. RESULTS:There is no interfere of every component between ethanol,DMF,acetic acid inside standard and solven. The resolution and sensitivity were acceptable. The detection limit of the three components were 2.03μg/mL, 2.21μg/mL, 3.75μg/mL respectively. CONCLUSIONS This method is accurate to control the organic solvents remaining.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2327) PDF downloads(315) Cited by()

Related
Proportional views

Method verify on quantity of organic solvents remaining

Abstract: OBJECTIVE To establish a GC method for the determination of organic solvents remaining. METHODS The methods was approved by high efficiency chlomatogram column of INNOWAX(30m×0.32mm×0.25μm),with a detector of FID using direct injection. RESULTS:There is no interfere of every component between ethanol,DMF,acetic acid inside standard and solven. The resolution and sensitivity were acceptable. The detection limit of the three components were 2.03μg/mL, 2.21μg/mL, 3.75μg/mL respectively. CONCLUSIONS This method is accurate to control the organic solvents remaining.

HAN Jia-yi, ZHENG Guo-gang. Method verify on quantity of organic solvents remaining[J]. Journal of Pharmaceutical Practice and Service, 2003, (6): 355-357.
Citation: HAN Jia-yi, ZHENG Guo-gang. Method verify on quantity of organic solvents remaining[J]. Journal of Pharmaceutical Practice and Service, 2003, (6): 355-357.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return