Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

YANG Hui-yuan, LE Jian, CHEN Gui-liang. Determination of dissolution of cloxacillin sodium capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (2): 83-85.
Citation: YANG Hui-yuan, LE Jian, CHEN Gui-liang. Determination of dissolution of cloxacillin sodium capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (2): 83-85.

Determination of dissolution of cloxacillin sodium capsule by HPLC

  • Received Date: 2003-08-21
  • Objective To establish a method for determine the dissolution of cloxacillin sodium capsule. Methods Separations were performed on a Lichrospher C18 (octadecyl silicane) column, using 0.02mol/L KH2PO4 solution(adjust to pH 5.0 with 8N sodium hydroxide)-aeetonitrile(75:25) as the mobile phase, the detection wavelength was 225nm. Result: The method showed the good linearity within the concentration range of 20.00~200.0μg/mL (r=0.9999 ) in assay. The average recovery was 100.4% (RSD=0.3%). The method of dissolution complies with Chinese pharmacopeia(Vol Ⅱ, 2000). Conclusion The method is accurate and simple, and suitable for the quality control of dissolution of cloxaeillin sodium capsule.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2563) PDF downloads(273) Cited by()

Related
Proportional views

Determination of dissolution of cloxacillin sodium capsule by HPLC

Abstract: Objective To establish a method for determine the dissolution of cloxacillin sodium capsule. Methods Separations were performed on a Lichrospher C18 (octadecyl silicane) column, using 0.02mol/L KH2PO4 solution(adjust to pH 5.0 with 8N sodium hydroxide)-aeetonitrile(75:25) as the mobile phase, the detection wavelength was 225nm. Result: The method showed the good linearity within the concentration range of 20.00~200.0μg/mL (r=0.9999 ) in assay. The average recovery was 100.4% (RSD=0.3%). The method of dissolution complies with Chinese pharmacopeia(Vol Ⅱ, 2000). Conclusion The method is accurate and simple, and suitable for the quality control of dissolution of cloxaeillin sodium capsule.

YANG Hui-yuan, LE Jian, CHEN Gui-liang. Determination of dissolution of cloxacillin sodium capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (2): 83-85.
Citation: YANG Hui-yuan, LE Jian, CHEN Gui-liang. Determination of dissolution of cloxacillin sodium capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (2): 83-85.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return