Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

LU Xiao-he, JIN Bao-fang, WANG Xiu-lai. Determination of icarrin in Yangjing capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2007, (1): 37-38,53.
Citation: LU Xiao-he, JIN Bao-fang, WANG Xiu-lai. Determination of icarrin in Yangjing capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2007, (1): 37-38,53.

Determination of icarrin in Yangjing capsule by HPLC

  • Received Date: 2006-09-18
  • Objective:To establish an HPLC method for determination of Icarrin in Yangjing Capsule. Methods: The determina- tion was performed on Phenomenex C18 column(250mm×4.6 mm,5μm).The mobile phase consisted of acetonitrile-water(30:70) with a flow rate of 0.8 mL/min.The detecting wavelength was at 270 nm. Results: The linear range of icarrin was 122.2~611.0 ng (r=0.9996).The average recovery was 98.2%(RSD:1.33% ). Conclusion: The established method is simple,convenient,accu- rate and reproducible,and suitable for the quality control of Icarrin content in Yangjing capsule.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2514) PDF downloads(254) Cited by()

Related
Proportional views

Determination of icarrin in Yangjing capsule by HPLC

Abstract: Objective:To establish an HPLC method for determination of Icarrin in Yangjing Capsule. Methods: The determina- tion was performed on Phenomenex C18 column(250mm×4.6 mm,5μm).The mobile phase consisted of acetonitrile-water(30:70) with a flow rate of 0.8 mL/min.The detecting wavelength was at 270 nm. Results: The linear range of icarrin was 122.2~611.0 ng (r=0.9996).The average recovery was 98.2%(RSD:1.33% ). Conclusion: The established method is simple,convenient,accu- rate and reproducible,and suitable for the quality control of Icarrin content in Yangjing capsule.

LU Xiao-he, JIN Bao-fang, WANG Xiu-lai. Determination of icarrin in Yangjing capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2007, (1): 37-38,53.
Citation: LU Xiao-he, JIN Bao-fang, WANG Xiu-lai. Determination of icarrin in Yangjing capsule by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2007, (1): 37-38,53.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return