Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

ZHENG Cheng, XIANG Zhi-min. Detection of gibenclamide and phenformin in Jiangtang capsule by liquid chromatography-electrospray Ionization tandem mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2007, (6): 388-390.
Citation: ZHENG Cheng, XIANG Zhi-min. Detection of gibenclamide and phenformin in Jiangtang capsule by liquid chromatography-electrospray Ionization tandem mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2007, (6): 388-390.

Detection of gibenclamide and phenformin in Jiangtang capsule by liquid chromatography-electrospray Ionization tandem mass spectrometry

  • Received Date: 2007-08-16
  • Objective :To establish a liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS-MS) for the identification of glibenclamide and phenformin illegally added in Jiangtang Capsule. Methods :The detection was performed on Altima C18 column with a mobile phase of acetonitrile-formic acid solution(65-35).The above compounds were identified by LC-MS-MS. Results :Glibenclamide and phenformin were detected illegally added in one sample of Jiangtang capsule. Conclusion :This is an effective method with characteristic and sensitivity for analysis of chemical drugs added in TCM.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2478) PDF downloads(42) Cited by()

Related
Proportional views

Detection of gibenclamide and phenformin in Jiangtang capsule by liquid chromatography-electrospray Ionization tandem mass spectrometry

Abstract: Objective :To establish a liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS-MS) for the identification of glibenclamide and phenformin illegally added in Jiangtang Capsule. Methods :The detection was performed on Altima C18 column with a mobile phase of acetonitrile-formic acid solution(65-35).The above compounds were identified by LC-MS-MS. Results :Glibenclamide and phenformin were detected illegally added in one sample of Jiangtang capsule. Conclusion :This is an effective method with characteristic and sensitivity for analysis of chemical drugs added in TCM.

ZHENG Cheng, XIANG Zhi-min. Detection of gibenclamide and phenformin in Jiangtang capsule by liquid chromatography-electrospray Ionization tandem mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2007, (6): 388-390.
Citation: ZHENG Cheng, XIANG Zhi-min. Detection of gibenclamide and phenformin in Jiangtang capsule by liquid chromatography-electrospray Ionization tandem mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2007, (6): 388-390.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return